Multipara Monitor Eva-N

Model: EVA-N

30,240

Compare
SKU:PM-HY-0111

ln-hospital application include emergency, pre-and post-operative care, ambulatory surgery, intermediate care/step down units, labor and hospital-based special procedure areas

Specifications:

ECG

Lead Mode : 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)

Lead selection: I, II, III, avR, avL, avF, V,

Waveform : 2 ch

Lead mode: 3 Leads ( R, L, F or RA, LA, LL) Lead selection : I, II, III, Waveform : 1 ch

Gain: 2.5mm/mV, 5.0mm/mV, lOmm/mV, 20mm/mV, auto

HR Alarm Range

Adult: 15 ~ 300 bpm

Neo/Ped : 15 ~ 350 bpm

Accuracy : ± 1% or ± 1 bpm,which great

Resolution : 1 bpm

Bandwidth
Surgery : 1 ~ 15 Hz
Monitor : 0.5 ~ 35 Hz

Diagnostic : 0.05 ~ 100 Hz

ST Segment Monitoring Range : Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting

Type : ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

RESPIRATION
Method : R-F(RA-LL) Impedance
Resp. Rate Measuring and Alarm Range
Adult : 0 ~ 1 20 rpm
Neo/Ped : 0 ~ 150 rpm
Resolution : 1 rpm
Accuracy : ±2 rpm
Apnea Alarm : 10 ~ 40s

NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Pulse Rate Range: 40 ~ 240 bpm
Alarm Type : SYS, DIA, MEAN
Measuring and alarm range
Adult Mode
SYS: 40 ~ 270 mmHg
DIA: 10 ~ 215 mmHg
MEAN: 20 ~ 235 mmHg
Pediatric Mode
SYS: 40 ~ 200 mmHg
DIA: 10 ~ 150 mmHg
MEAN: 20 ~ 165 mmHg
Neonatal Mode
SYS: 40 ~ 135 mmHg
DIA: 10 ~ 100 mmHg
MEAN: 20 ~ 1 10 mmHg
Resolution Pressure: lmmHg
Accuracy Pressure Maximum Mean error : ±5 mmHg

Overpressure Protection
Adult Mode: 297±3 mmHg
Pediatric Mode: 240±3 mHg
Neonatal Mode: 147±3 mmHg

Sp02
Measuring Range : 0 ~ 100 % Alarm Range : 0 ~ 100 % Resolution : 1 %
Accuracy : 70% ~ 100% ±2 %
0% ~ 69% unspecified

Pulse Rate
Measuring and Alarm Range: 20~300bpm
Resolution: 1 bpm
Accuracy: ±2bpm

Temperature
Channel: 2
Measuring and Alarm Range: 0 ~ 50°C
Resolution: 0.1 °C
Accuracy: ±0.1 °C

IBP
Label: ART, PA, CVP, RAP, LAP, ICP, PI, P2
Measuring and alarm range
ART: 0 ~ 300 mmHg
PA: -6 ~ 1 20 mmHg
CVP/RAP/LAP/ICP: -10 ~ 40 mmHg
P1/P2: -10 ~ 300 mmHg
Press Sensor Sensitivity: 5uV/V/mmHg Impedance: 300-3000Q
Resolution: 1 mmHg
Accuracy: ±2% or ± 1 mmHg, which is greater
Actualization interval : about Is
Dimension: 320 x 160 x 270mm
Net Weight : <5kg
Gross Weight : <8kg

Features:

  • Advanced streamline outline design, compact, lightweight, in-built handle makes it truly portable
  • Can be used to monitor adult, pediatric & neonate patient
  • Low perfusion working possible
  • Various display screen : Trend Coexist Display, OxyCRG Dynamic View Display, Bed to Bed view Display
  • Arrhythmia Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S-T segment analysis, pacemaker detection Drug calculation and titration table
  • Networking capacity and nurse call system
  • Large volume of tabular and graphic trends information storage and easy to recall
  • Capture dynamic waveforms
  • In-built Rechargeable battery which provides a backup time of upto 4 hours
  • User friendly menu structure with easy to use rotary dial
  • Protection Against electrosurgical interference and defibrillation
  • Intelligent audio and visual comprehensive alarm. Volume adjustment possible
  • Standard Configuration :
    ECG, HR, Sp02, ST Analysis, Resp, NIBP, 2* Temp, Drug Dose Calculator, built in battery
  • Optional Configuration :
    Recorder, 2*IBP, EtC02 (Main Stream or Side Stream)

Additional Information:

  • One Year Warranty

 