The ABM DF-11 is a biphasic defibrillator that can deliver 70–100 shocks on a single charge. It supports both adult and pediatric paddles and is compact and lightweight. It also offers variable energy level selection, ranging from 2–200 joules.
Defibrillators are devices that use an electric charge or current to restore a normal heartbeat. They can help the heart start beating again if its rhythm stops due to cardiac arrest.
Specification:
OPTIONAL :AED, Pacer, Sp02, NIBP, EtC02,
Internal Paddle, 360 Joules
Display 7 Inch Color TFT
Display Area: 150 mm x 90 mm
Dimensions H 280 x W 330 x D 220 mm (Max) without Paddle
Weight Approx. 6 Kgs. Max.
Unit ON-OFF By front panel push bunon
Operation By front panel keyboard, Encoder
Alarm User adjustable high & low limit. Audible and visual
alarming
Trend 24 hrs. graphical and tabular trend of ECG,Sp02, NIBP,EtC02
Charge/ Discharge Charge and Shock buttons on front panel and Control paddles
POWER SUPPLY Input 150-270 VAC, 50 Hz 10
Battery 12 V 4.5Ah, Rechargeable
Battery capacity 3 hours for monitor and 70-100 shocks on full charge
LED indicator Low battery and battery charging
Power consumption 30 Watts (max) in ECG mode
ENVIRONMENTAL
Operating Temp +5°C to +5°C
Humidity up to 95% non-condensing
Defib (External Paddles)
Operating Mode Manual
Waveform Biphasic Truncated Exponential
Energy 2 to 200 joules in 12 steps selection
Energy display Displays selected and charged/delivered energy Energy delivery begins within 60 ms of the ORS Peak
Charging Time 6 seconds on Mains
Paddle Assembly External paddle assembly with coil retractable high voltage cable. Adults & Pediatric paddle integrated to same handle
Check Mode Manual check mode
Patient Impedance range 35 ohm to 250 ohm
Shock Delivery Through paddles or pads
Defib (Internal Paddles) (Optional)
Operating Mode Manual
Waveform Biphasic Truncated Exponential
Energy 2 to 50 joules in 8 steps selection
Synchronous Cardio Energy delivery begins within 60 ms of
Version the ORS Peak
Charging Time 6 seconds on Mains
Paddle Assembly Internal paddle assembly with paddle extension cord
ECG
Frequency response 0.5 Hz to 35 Hz
Patient isolation Optical isolation
Lead selection Lead I, II and Ill
Gain setting CMRR 0.5, 1.0 and 2.0
Sweep speed 12.5, 25.0, 50.0 mm/sec
Digital filter Digital signal processing for good quality of ECG
ECG traces viewing 4 seconds of ECG traces
HEART RATE
Range 10-250 BPM
Accuracy +/– 2 BPM
Resolution 1 BPM
Tone Beep on every ORS detected
Alarm limit setting 10-250 (step of 1)
PRINTER
Paper Type Thermal paper 50/55mm width, 20 meters length for 2 inch printer
Event Printing Prints 5 seconds pre & post ECG with Date, Time Energy and mode.Shock Status
ECG in Defitl Mode Prints last 10 sec ECG through paddle
Print Annotates in Time, Date, Mode, lead name, gain, sweep speedDefib Mode
ECG in Monitor Prints last 10 sec ECG through cable
Mode Print Annotates in Time,Date,selected lea name, Gain Sweep speed
Monitor Mode Prints the status of Shock, Energy, Date and Time Mode
Manual Defit> Check
Sp02 (Optional)
Systolic,Diastolic and Mean arterial pressure
Range 0 -100%Accuracy:70 -100% + 2digits,50 – 69% + 3 digits
Pulse rate Displayed in ECG window, when PR is selected
Pulse beep Yes, with volume control
PR range : 10 to 250 bpm ( +/-2bpm)
Pitch variation with change in oxygen saturation
NIBP (Optional)
Systolic,Diastolic and Mean arterial pressure
Method Oscillometric
NIBP interval User selectable – 2 min. to 25min.
Modes Manual, auto
Cuff deflation Automatic
Safety features Automatic deflation if cuff pressure exceeds 280mmHg
NIBP status display “Ready”, when not taking reading as “Measuring”, when taking reading and “Error, if
reading could not be taken due to some error while measuring
Patient Type Adult, Pediatric, Neonate
AED Mode (Optional)
PACER (Optional)
Wave form Mon aphasic
Modes Demand or Non Demand
Pulse Current From 1 OmA to 150 mA ( resolution of 1 O mA),
Pulse Duration 40 ms (+/-1ms)
Pacing rate From 20 ppm to 250 ppm (increments of 1 ppm)
Refractory period 340ms (from30 to80ppm);240ms(from90 to180ppm)
Maximum output 150 voltage
Impedance range 200 ohm to 1 k ohm
EtC02 (Optional)
Parameter EtC02,RR
Adaptor Adult, Pediatric, Neonate
Measurement Mode Mainstream & side stream
EtC02 Range 0-100mmhg
Accuracy +!- 2 mmHg
Respiration Range 0-120 bpm
Features:
- 7-inch TFT display
- Offers variable energy level selection. ( 20,30,50,70,100,150,200, Joules)
- 24 hrs. graphical & tabular trend of ECG,Spo2 ,NIBP & ETCO2
- Charge & shock buttons on the front panel & control panel
- Optional Parameters: AED, Pacing, ,NIBP, SPO2, ETCO2 , Internal Defibrillation
- Weight is approximately 6 kg.
- Adult & pediatric Paddles support.
- ECG through paddles in defi mode & print the last 10 sec.
- Biphasic truncated experimental waveform.
- The charging time is 6 seconds on mains
Additional Information:
- One Year Warranty
- Weight :7kg
Reviews